SP5-xxx: Mode-1
G179 5-46 SM
There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the
first digit, so the eight-digit setting for -2 or -3 becomes a seven-digit setting.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour /step]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes /step]
For example: 3500010
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March.
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
Rule Set (End)
004
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
Access Control (DFU)
5401*
This SP stores the settings that limit uses access to SDK application data.
200 SDK1 Unique ID
201 SDK1 Certification Method
210 SDK2 Unique ID
211 SDK2 Certification Method
220 SDK3 Unique ID
"SDK" is the "Software
Development Kit". This data can
be converted from SAS (VAS)
when installed or uninstalled.
(DFU)