SP7-xxx: Data Log-2
G179 5-108 SM
PCD
[0 to 255 / 0 / 1 ]
001
Displays the replacement counter of the PCD (Drum and Development unit).
Transfer
[0 to 1 / 0 / 1 ]
002
Displays the replacement counter of the transfer unit.
Fusing
[0 to 1 / 0 / 1 ]
003
Displays the replacement counter of the fusing unit.
Web
[0 to 1 / 0 / 1 ]
004
Displays the replacement counter of the cleaning web.
Zero Cross
[0 to 255 / 60 / 1 ]
7856* 1
Stores and displays the detected zero cross frequency of the main ac power
supply from the wall socket.
Assert Info [DFU]
7901
Records the location where SC990 is detected in the program. The data
stored in this SP is used for problem analysis.
001 File Name
002 Number of Lines
003 Location
Near End Setting
7904*
Sets the near end setting for each maintenance items.
001 PCD
002 Transfer
003 Fusing
[0 to 2 / 1 / 1 /step]
0: Earlier, 1: Default, 2: Nearly Limit