Using SP Modes
SM 5-155 G179
Service
Tables
No. Item What It Initializes
003 SCS System Control Service (ROM update information)
004 IMH Memory Clr Image Memory Handler
008 Printer Printer defaults
010 GWWS/NFA
Netfile (NFA) management files, thumbnails, the Job
login ID.
011 NCS
Network Control Service. IP addresses,
SmartDeviceMonitor for Admin., Web Status Monitor
settings, TELNET settings
014 Clear DCS Setting DCS (Delivery Control Service) settings
015 Clear UCS Settings User Information Control Service settings
016 MIRS Settings Machine Information Report Service settings
017 CCS Certification and Charge-control Service settings.
018 SRM Memory Clr System Resource Management settings
019 LCS Log Count Service settings
021 ECS
8. After clearing all settings, make sure that you do the following:
Do the laser beam pitch adjustment. ( LD Unit in the section “Replacement and
Adjustment)
Referring to the SMC Report, re-enter any values, which had been changed from
their factory settings.