Electrical Components
326
1. Print the Box List with the User Tools/Counter.
• [User Tools/Counter] - [Facsimile Features] - [General Settings] - [Box Setting: Print List]
2. Print the Special Sender List by pressing these buttons in the following order.
• [User Tools/Counter] - [Facsimile Features] - [Reception Settings] - [Program Special Sender:
Print List]
3. Write down the following fax settings.
• [Receiver] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] - [Reception
File Settings] - [Forwarding].
• [Notify Destination] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] -
[Reception File Settings] - [Store].
• [Specify User] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] - [Stored
Reception File User Setting].
• [Notify Destination] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] -
[Folder Transfer Result Report].
• Specified folder in [User Tools/Counter] - [Facsimile Features] - [Send Settings] - [Backup File
TX Setting].
• [Receiver] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] - [Reception
File Settings] - [Output Mode Switch Timer].
• [Store: Notify Destination] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings]
- [Output Mode Switch Timer].
• All the destination information shown on the display.
• In the fax settings, address book data is stored with entry IDs, which the system internally
assigns to each data. The entry IDs may be changed due to re-assigning in backup/restore
operations.
4. Make sure that there is no transmission standby file. If any standby file exists, ask the customer to
delete it or complete the transmission.
8.
Turn the main power OFF and unplug the power supply cord.
9. Push the main power switch ON again to discharge the residual charge.
10. Replace the NV-RAM with a new one.
11. Turn the power ON.
• SC673 appears at start-up, but this is normal behavior. This is because the controller and the
smart operation panel cannot communicate with each other due to changing the SP settings for
the operation panel.
1. Change the SP settings for the operation panel.
• SP5-748-101: (OpePanel Setting: Op Type Action Setting): Change bit 0 from “0” to “1”.
• SP5-748-201: (OpePanel Setting: Cheetah Panel Connect Setting): Change the value from “0” to
“1”.