3.SP Mode Tables
47
SP Tables - SP2-XXX (1)
SP2-XXX (Drum) -1
SP
No.
Large Category Small Category ENG or
CTL
[Min to
Max/Init./Step]
2-
005-
001
Charge DC Voltage: Fix Plain: Bk ENG* [ 0 to 2000 / 590 / 10-
V ]
2-
005-
002
Charge DC Voltage: Fix Plain: C ENG* [ 0 to 2000 / 590 / 10-
V ]
2-
005-
003
Charge DC Voltage: Fix Plain: M ENG* [ 0 to 2000 / 590 / 10-
V ]
2-
005-
004
Charge DC Voltage: Fix Plain: Y ENG* [ 0 to 2000 / 590 / 10-
V ]
2-
013-
001
Environmental Correction: PCU Environment Div. FC:
Display
ENG* [ 0 to 5 / 0 / 1 ]
2-
013-
002
Environmental Correction: PCU Forced Setting ENG* [ 0 to 5 / 0 / 1 ]
2-
016-
001
Lubricant Apply Operation Temperature Threshold:
Low
ENG* [ 0 to 50 / 15 / 1deg ]
2-
016-
002
Lubricant Apply Operation Temperature Threshold:
High
ENG* [ 0 to 50 / 30 / 1deg ]
2-
016-
003
Lubricant Apply Operation Page Setting 1: Low Speed ENG* [ 0 to 999 / 10 /
1page ]
2-
016-
004
Lubricant Apply Operation Page Setting 2: Low Temp. ENG* [ 0 to 999 / 20 /
1page ]
2-
016-
005
Lubricant Apply Operation Page Setting 3: Low Temp.
2
ENG* [ 0 to 999 / 0 / 1page ]