3.SP Mode Tables
46
002
1-951-
003
Fan Start Time Set PSU Fan ENG* [ 0 to 120 / 0 / 1sec ]
1-951-
004
Fan Start Time Set Laser Unit Fan ENG* [ 0 to 120 / 0 / 1sec ]
1-952-
001
Fan Control Off Mode
Time Set
ENG* [ 10 to 60 / 10 / 1min ]
1-953-
001
Extra Fan Control Operation Status ENG* [ 0 or 1 / 0 / 1 ]
1-953-
006
Extra Fan Control Extra Fan Start Temp. ENG* [ 0 to 50 / 5 / 0.1deg ]
1-953-
007
Extra Fan Control Extra Fan Stop Temp. Threshold ENG* [ 0 to 50 / 2 / 0.1deg ]
1-953-
008
Extra Fan Control Set: Extra Operation ON/OFF ENG* [ 0 or 1 / 1 / 1 ]
1-955-
001
Fan Control PCDU Fan Operation Sw Temp. ENG* [ 0 to 100 / 38 /
0.1deg ]
1-955-
002
Fan Control Fusing Fan Operation Sw Temp. ENG* [ 0 to 100 / 0 / 0.1deg ]
1-955-
004
Fan Control Laser Unit Fan Operation Sw Temp. ENG* [ 0 to 100 / 38 /
0.1deg ]
1-955-
005
Fan Control Fan Operation Sw Temp. Threshold ENG* [ 0 to 100 / 2 / 0.1deg ]
1-955-
006
Fan Control PSU Fan Operation Start Time2 ENG* [ 0 to 900 / 0 / 1sec ]
1-955-
007
Fan Control PSU Fan Ctrl Off Mode Time2 ENG* [ 0 to 60 / 10 /
0.1min. ]