3.SP Mode Tables
45
077 Adj. Mid Speed
1-907-
078
Paper Feed Timing
Adj.
Exit Clutch ON: Mid Speed ENG [ -20 to 20 / 0 / 1mm ]
1-907-
079
Paper Feed Timing
Adj.
Invert Clutch OFF: Invert : Plain ENG [ -20 to 20 / 0 / 1mm ]
1-907-
080
Paper Feed Timing
Adj.
Invert Clutch OFF:1bin Exit: Plain ENG [ -20 to 20 / 0 / 1mm ]
1-907-
081
Paper Feed Timing
Adj.
Invert Clutch ON: Plain ENG [ -20 to 20 / 0 / 1mm ]
1-907-
082
Paper Feed Timing
Adj.
Invert Clutch OFF: Invert:Std Speed
2
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
083
Paper Feed Timing
Adj.
Invert Clutch OFF:1BIN: Std Speed
2
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
084
Paper Feed Timing
Adj.
Invert Clutch ON: Std Speed 2 ENG [ -20 to 20 / 0 / 1mm ]
1-907-
085
Paper Feed Timing
Adj.
Invert Clutch OFF: Invert: Low
Speed
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
086
Paper Feed Timing
Adj.
Invert Clutch OFF:1BIN: Low
Speed
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
087
Paper Feed Timing
Adj.
Invert Clutch ON: Low Speed ENG [ -20 to 20 / 0 / 1mm ]
1-907-
088
Paper Feed Timing
Adj.
Invert Clutch OFF: Invert :Mid
Speed
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
089
Paper Feed Timing
Adj.
Invert Clutch OFF:1BIN: Mid
Speed
ENG [ -20 to 20 / 0 / 1mm ]
1-907-
090
Paper Feed Timing
Adj.
Invert Clutch ON: Mid Speed ENG [ -20 to 20 / 0 / 1mm ]
1-950-
001
Fan Cooling Time Set PCDU Cooling Fan ENG* [ 0 to 600 / 0 / 1sec ]
1-950-
002
Fan Cooling Time Set Fusing Fan ENG* [ 0 to 600 / 10 / 1sec ]
1-950-
003
Fan Cooling Time Set PSU Fan ENG* [ 0 to 600 / 0 / 1sec ]
1-950-
004
Fan Cooling Time Set Laser Unit Fan ENG* [ 0 to 600 / 0 / 1sec ]
1-951-
001
Fan Start Time Set PCDU Cooling Fan ENG* [ 0 to 120 / 0 / 1sec ]
1-951- Fan Start Time Set Fusing Fan ENG* [ 0 to 120 / 0 / 1sec ]