SC8xx: Overall System
466
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
[XXXX]: Detailed error code
[0001] TLB change (store) exception error
[0002] TLB miss (load) exception error
[0003] TLB miss (store) exception error
[0004] Read address exception error
[0005] Write address exception error
[0006] Instruction bus exception error
[0007] Data bus exception error
[0008] System call exception error
[0009] Break exception error
[000A] Invalid instruction exception error
[000B] Co-processor exception error
[000C] Overflow exception error
[000D] UTLB miss exception error
[0010] Interrupt line 0 error
[0011] Interrupt line 1 error
[0012] Interrupt line 2 error
[0013] Interrupt line 3 error
[0014] Interrupt line 4 error
[0015] Interrupt line 5 error
Unexpected exception or interrupt occurred
CPU device error
The boot monitor program or self-diagnostic program is broken.
Replace the controller board
Reinstall the controller system software.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[00FF] Uninitialized interrupt error
Cache error (such as a parity error) occurred.
CPU device error
Local bus defective
Cycle the main power off and on.
Reinstall the controller system software.
Replace the controller board
Replace the connected controller option with a new one.