3.SP Mode Tables
167
3-539-
064
Dev Agitating Time: Set Dot Coverage Threshold:
4
ENG* [ 0 to 100 / 60 / 1% ]
3-539-
065
Dev Agitating Time: Set Dot Coverage Threshold:
5
ENG* [ 0 to 100 / 80 / 1% ]
3-539-
099
Dev Agitating Time: Set Upper Limit ENG* [ 0 to 3600 / 30 / 1sec ]
3-541-
001
Music Interval :Set Page Counter: BW ENG* [ 0 to 5000 / 0 / 1sheet ]
3-541-
002
Music Interval :Set Page Counter: FC ENG* [ 0 to 5000 / 0 / 1sheet ]
3-550-
001
Refresh Mode Required Area: Bk ENG* [ 0 to 65535 / 0 / 1cm2 ]
3-550-
002
Refresh Mode Required Area: C ENG* [ 0 to 65535 / 0 / 1cm2 ]
3-550-
003
Refresh Mode Required Area: M ENG* [ 0 to 65535 / 0 / 1cm2 ]
3-550-
004
Refresh Mode Required Area: Y ENG* [ 0 to 65535 / 0 / 1cm2 ]
3-550-
011
Refresh Mode Dev. Motor Rotation:
Display: Bk
ENG* [ 0 to 1000 / 0 / 0.1m ]
3-550-
012
Refresh Mode Dev. Motor Rotation:
Display: C
ENG* [ 0 to 1000 / 0 / 0.1m ]
3-550-
013
Refresh Mode Dev. Motor Rotation:
Display: M
ENG* [ 0 to 1000 / 0 / 0.1m ]
3-550-
014
Refresh Mode Dev. Motor Rotation:
Display: Y
ENG* [ 0 to 1000 / 0 / 0.1m ]
3-550-
021
Refresh Mode Rotation Threshold ENG* [ 0 to 1000 / 0.1 / 0.1m ]
3-550-
031
Refresh Mode Refresh Threshold: Bk ENG* [ 0 to 255 / 25 / 1cm2/m ]
3-550-
032
Refresh Mode Refresh Threshold: C ENG* [ 0 to 255 / 25 / 1cm2/m ]
3-550-
033
Refresh Mode Refresh Threshold: M ENG* [ 0 to 255 / 25 / 1cm2/m ]
3-550-
034
Refresh Mode Refresh Threshold: Y ENG* [ 0 to 255 / 25 / 1cm2/m ]
3-550-
041
Refresh Mode Job End Area Coefficient ENG* [ 0.1 to 25.5 / 1 / 0.1 ]