3.SP Mode Tables
169
3-600-
001
Select ProCon Potential Control ENG* [ 0 or 1 / 1 / 1 ]
0: FIXED
1: CONTROL
3-600-
002
Select ProCon LD Control ENG* [ 0 to 3 / 1 / 1 ]
0: OFF
1: ON
3-600-
003
Select ProCon TC Adj. Mode ENG* [ 0 to 3 / 3 / 1 ]
0: Do Not Execute
1: 1st Power On
2: 1st Power On & Job End
3: Dev gamma judgment
3-600-
004
Select ProCon ACC Before ProCon ENG* [ 0 to 3 / 2 / 1 ]
0: Not Execute
1: Process Control
2: TC Control
3-600-
060
Select ProCon Vsg ITB Prev Pattern
Corr.
ENG* [ 0 to 2 / 2 / 1 ]
0: OFF
1: All Time
2: Non-use Time (Long)
3-610-
001
Charging AC Control:
Display
Standard Speed: Bk ENG* [ 0 to 3 / 2.1 / 0.01kV ]
3-610-
002
Charging AC Control:
Display
Standard Speed: C ENG* [ 0 to 3 / 2.1 / 0.01kV ]
3-610-
003
Charging AC Control:
Display
Standard Speed: M ENG* [ 0 to 3 / 2.1 / 0.01kV ]
3-610-
004
Charging AC Control:
Display
Standard Speed: Y ENG* [ 0 to 3 / 2.1 / 0.01kV ]
3-611-
001
Charging DC Control:
Display
Standard Speed: Bk ENG* [ 300 to 1000 / 700 / 1-V ]
3-611-
002
Charging DC Control:
Display
Standard Speed: C ENG* [ 300 to 1000 / 690 / 1-V ]
3-611-
003
Charging DC Control:
Display
Standard Speed: M ENG* [ 300 to 1000 / 690 / 1-V ]
3-611-
004
Charging DC Control:
Display
Standard Speed: Y ENG* [ 300 to 1000 / 690 / 1-V ]
3-611-
011
Charging DC Control:
Display
Mid Speed: Bk ENG* [ 300 to 1000 / 700 / 1-V ]
3-611- Charging DC Control: Mid Speed: C ENG* [ 300 to 1000 / 690 / 1-V ]