3.SP Mode Tables
185
008
4-417-
001
IPU Test Pattern Test Pattern ENG [ 0 to 8 / 0 / 1 ]
0: Scanned image
1: Gradation main scan
A
2: Patch 16C
3: Grid pattern A
4: Slant grid pattern B
5: Slant grid pattern C
6: Slant grid pattern D
7: Scanned+Slant Grid
C
8: Scanned+Slant Grid
D
4-429-
001
Select Copy Data
Security
Copying ENG [ 0 to 3 / 3 / 1 ]
4-429-
002
Select Copy Data
Security
Scanning ENG [ 0 to 3 / 3 / 1 ]
4-429-
003
Select Copy Data
Security
Fax Operation ENG [ 0 to 3 / 3 / 1 ]
4-460-
001
Digital AE Low Limit Value ENG [ 0 to 1023 / 364 / 1 ]
4-460-
002
Digital AE Background level ENG* [ 512 to 1535 / 932 / 1 ]
4-501-
001
ACC Target Den Copy:K:Text ENG* [ 0 to 10 / 5 / 1 ]
4-501-
002
ACC Target Den Copy:C:Text ENG* [ 0 to 10 / 5 / 1 ]
4-501-
003
ACC Target Den Copy:M:Text ENG* [ 0 to 10 / 5 / 1 ]
4-501-
004
ACC Target Den Copy:Y:Text ENG* [ 0 to 10 / 5 / 1 ]
4-501-
005
ACC Target Den Copy:K:Photo ENG* [ 0 to 10 / 5 / 1 ]
4-501-
006
ACC Target Den Copy:C:Photo ENG* [ 0 to 10 / 5 / 1 ]
4-501-
007
ACC Target Den Copy:M:Photo ENG* [ 0 to 10 / 5 / 1 ]