Technical Bulletin PAGE: 1/2
Reissued: 12-Jul-11
Model: Aries-P1.5 Date: 04-Oct-10 No.: RM077004b
RTB Reissue
The items in bold italics have been corrected.
Subject: Firmware Release Note: Network Support Prepared by: H.Kawamura
From: PPBG Service Planning Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the Network
Support.
Version Program No. Effective Date
7.12 M0776092C July 2011 production
7.11 M0776092B February 2011 production
7.10 M0776092A 1st Mass production
Version Modified Points or Symptom Corrected
7.12 Modified Points
- If SSDP = Active (Web ImageMonitor > Configuration > Network
Security), a high load on the CPU might result in Web ImageMonitor
locking up.
- LP with an external controller will lose network connectivity. This
only occurred if the network settings were changed repeatedly and
the LP's "NetWare" setting was already "Active" (before the network
settings were changed).
- The LP icon might not be shown in the Windows "Network" dialogue
if SSDP is enabled. This affected Windows Vista, 2008/R2, and 7.
- The device might lose network connectivity if SSDP is enabled.
Network connectivity could be temporarily restored after a power
cycle.
Following firmware need to be upgraded together
Part number version
Engine M0775252E 1.006:16
System/Copy M0776091E 1.04
Websys M0776093C 1.02
Ope Panel CHN M0776387 1.05
Ope Panel NA M0776385C 1.05
Ope Panel EU M0776386C 1.05
Language M0776390B 1.04
Network Support M0776692C 7.12