EasyManua.ls Logo

Ricoh pro c901 - RTB 76: “0218: Adjust Maximum Image Density

Ricoh pro c901
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T
echnical
B
ulletin PAGE: 1/1
Model:
Aries-P1.5/C1.5, AG-P1/C1
Date:
01-Oct-12
No.:
RM077076
Subject:
Notice of Failure - Adjustment #0218 of Adjustment
Setting for Skilled Operators
Prepared by:
Hidetoshi Kawamura
From:
PP Tech Service Dept., 1st PP Tech Service Sect.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other ( ) Tier 2
General
“0218: Adjust Maximum Image Density” of the Adjustment Setting for Skilled Operators
menu was found with a failure as described in ‘Symptom’ below. Until a solution
becomes available, it is requested to field technicians and users to refrain from applying
this adjustment. As a workaround, adjust the maximum toner amount in the SP mode
as this will substitute the effect generated by “0218: Adjust Maximum Image Density.”
Symptom
While adjustment made in “0218: Adjust Maximum Image Density” changes the target
value for process control in order to achieve the target image density, once process
control is executed during a job, the system will ignore the adjustment made in “0218”
and return to the default process control target value.
Cause
Software bug
Solution
Bug fix: TBD
Workaround
1. Set the value for “0218: Adjust Maximum Image Density” to “0”.
2. Apply the following SP setting.
SP Color Default -5 -4 -3 -2 -1 +1 +2 +3 +4 +5
3-531-
001
Bk
3-531-
002
C
3-531-
003
M
3-531-
004
Y
0.476 0.376 0.396 0.416 0.436 0.456 0.496 0.516 0.536 0.556 0.576
Important: DO NOT apply a value higher than 0.576.
3. Execute process control (SP 3820-002) for the above SP modification to take effect.