Technical Bulletin PAGE: 1/1
Model: Aries-P1.5/C1.5 Date: 13-May-11 No.: RM077029
Subject: Fusing Cleaning Web Near-end Not Detected Prepared by: Hiroaki Matsui
From: 1st PP Service Planning Sec., PP Service Planning
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other ( )
Action required
Service manual revision
Retrofit information
Tier 2
SYMPTOM
Near-end for the Fusing Cleaning Web is not detected; near-end alert is not displayed on
the operation panel.
CAUSE
System F/W problem
SOLUTION
System F/W will be fixed to detect Cleaning Web near-end and display the alert.
TEMPORARY SOLUTION
Please check the remaining service life of the Cleaning Web during your next service visit
and replace the Web Cleaning Unit if it is expected to reach its service life before your next
visit.
Reference
The current System F/W could detect Cleaning Web near-end and display the alert if
SP5062-001 (Parts PM Display Setting) is set to “ON”. (The default is “OFF”.)
However, setting this SP to “ON” will also display near-end alerts for all other PM parts,
and may appear confusing on the operation panel.