EasyManua.ls Logo

Ricoh pro c901 - RTB 73: Procedure for Adjusting the CIS LED

Ricoh pro c901
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T
echnical
B
ulletin PAGE: 1/3
Model:
Aries-P1.5/C1.5, AG-P1/C1, AGL-P1/C1
Date:
06-Jun-12
No.:
RM077073
Subject:
Procedure for Adjusting the CIS LED upon
Replacement of the CIS Unit
Prepared by: J. Kobayashi
From:
PP Tech Service Dept., 1st PP Tech Service Sect.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (Additional
Information)
Action required
Service manual revision
Retrofit information
Tier 2
This RTB has been issued to announce the CIS LED adjustment procedure which is
required when replacing the CIS unit.
Please add this procedure to your field service manual in the section:
4. Replacement and Adjustments > Paper Registration > CIS Unit
Procedure
TCRU screws
1. Remove the cover [A]. (TCRU screw x 2)
Screws
Connector
2. Remove the CIS unit [A]. screw x2, connector x1
[A]
[A]