Technical Bulletin PAGE: 1/1
Model: Aries-P1.5/C1.5
Date: 28-Jul-14
No.: RM077115
Subject: DOSS (Data overwrite security system) activation
procedure
Prepared by: T. Miyamoto
From: 1st Tech service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other ( )
Action required
Service manual revision
Retrofit information
Tier 2
Please add the following procedure for activating the DOSS (data overwrite security
system) to your field service manual in the following section:
2. Installation > MFP Option
DOSS (data overwrite security system) Activation Procedure
1) Go into the SP mode.
2) Select SP5-878-001 “Option Setup” and push “Execute” on the operation panel.
3) Turn the machine power off and then on.
NOTE:
DOSS is a standard function of the ProC901/901S. An SD card is unnecessary for
DOSS installation and activation.
DOSS on the ProC901/901S does not support CC (common criteria) certification.