Technical Bulletin PAGE: 1/2
Model: Aries-P1.5/C1.5 Date: 21-Dec-10 No.: RM077012
Subject: Counter Display Prepared by: Hidetoshi Kawamura
From: PPBG Service Planning Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other ( ) Tier 2
The Service Manual for Aries-P1.5/C1.5 was corrected
• On pages 603 in the appendix
• SP 5045 “Accounting Counter”
Correction
Original
NOTE: The counting method can be changed only once, regardless of whether the counter
value is negative or positive.
Correction
NOTE: Aries-P1.5: The counting method can be changed only once, regardless of whether
the counter value is negative or positive.
Aries C1.5: The counting method can be changed many times, regardless of whether the
counter value is negative or positive.
Original
SP5041-001 Counter Method 0: Developer
1: Prints
Correction
SP5041-001 Counter Method 0: Developer
1: Prints
2: Coverage
3: Not used
4: Not used
5: Developer (A3/DLT & Larger)
6: Prints (A3/DLT & Larger)
Please change the setting of Counter Method by following the contract type with the
customer.
Note
Default Counter Method settings are different between Aries P1.5 and Aries C1.5.
Aries P1.5’s default setting is set as: SP 5041-001-1, “Prints” and it can be only changed
once
Aries C1.5’s default setting is set as: SP-5041-001- 0, “Developer” and it can be changed
many times.
Supplementary explanation of “Developer (A3/DLT & Larger)” and “Prints (A3/DLT &
Larger)”