Technical Bulletin PAGE: 1/1
Reissued:19-May-11
Model: Aries-P1.5/C1.5 Date: 13-May-11 No.: RM077030a
RTB Reissue
The items in bold italics were corrected.
SYMPTOM
When performing the following 2 output checks waste toner could clog and disable the function of
the toner collection coil, which could result in breakage of the gear rotating the waste toner
transport coil, and toner leakage.
Toner Fill (SP2253 -001:K, -002:C, -003:M, -004:Y, -005:Col, -006:All Color)
Init TD Sensor (SP3801 -001:All Color, -002:Col, -003:K, -004:C, -005:M, -006:Y)
CAUSE
Waste toner clog
TEMPORARY SOLUTION
Output Check Required Additional Procedure
Toner Fill
(SP2253-001:K, -002:C, -003:M, -
004:Y, -005:Col, -006:All Color)
Init TD Sensor
(SP3801-001:All Color, -002:M, -
003:K, -004:C, -005:M, -006:Y)
Do the following output checks together:
Waste Toner Transport Motor 1 (SP5804-152)
Waste Toner Transport Motor 2 (SP5804-153)
SOLUTION
F/W will be modified.(Release schedule : TBD)
Subject: Additional output check when toner feeding Prepared by: Hiroaki Matsui
From: 1st PP Service Planning Sec., PP Service Planning
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other ( )
Action required
Service manual revision
Retrofit information
Tier 2
Toner clogging could cause breakage of
this idling gear for waste toner transport.
Not cut in D-shape