Technical Bulletin PAGE: 1/8
Reissued:06-Jan-12
Model: Aries-P1.5/C1.5 Date: 15-Jul-11 No.: RM077042a
RTB Reissue
The items in bold italics were corrected or added.
General
Conventionally, one fusing unit was assigned for one mainframe. Multiple fusing units
could not be assigned for one mainframe because the mainframe could only manage the
PM counter for one fusing unit.
The system has been modified to enable application of multiple fusing units per mainframe
and independent PM counter management accordingly.
The main purpose of this system modification is to prevent image quality problems caused
by a damaged fusing belt. Continuous feeding of a particular paper size causes the paper
edges to damage the fusing belt, which generates a line on the output image when
changing to a larger paper size.
Requirements
This modification will become available by installing the firmware versions listed below.
Pro C901
Part number Version
Engine M0775252D 1.005:16
System M0776091D 1.03
Websys M0776093B 1.01
Ope Panel NA M0776385B 1.04
Ope Panel EU M0776386B 1.04
Language M0776390A 1.03
Pro C901
Part number Version
Engine D0955252D 1.005:16
System D0956091C 1.03
Websys D0956093B 1.01
Ope Panel NA M0776395B 1.02
Ope Panel EU M0776396B 1.02
Language M0776391A 1.02
Subject: New Management procedure of multi fusing unit Prepared by: Hiroaki Matsui
From: 1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other ( ) Tier 2

Table of Contents