Technical Bulletin PAGE: 4/4
Model: Aries-P1.5/C1.5 Date: 11-Jul-11 No.: RM077041
Appendix
The diagram below shows the differences between the Original Guide Plate and the Modified
Guide Plate.
Original (Type AD) Modified (Type AX)
Distance between ITB and Guide Plate: 2.1mm
Distance between nip and Guide Plate: 11.7mm
Length of Mylar A (green): 12mm
Length of Mylar B (blue): 16mm
Distance between ITB and Guide Plate: 2.5mm
Distance between nip and Guide Plate: 21.9mm
Length of Mylar A (green): 10mm
Length of Mylar B (blue): 12mm
NOTE
The “Cover: 1
st
Transfer Ass’y” may come with Mylars (0~3 pcs) as an accessory depending on the finishing
precision of the Cover. Attach the Mylar(s) to secure optimum distance between the Cover: 1
st
Transfer
Ass’y and the guide plate when applying the ITB Guide Plate Type AX.
用紙
導電性PE
PC
板金
板金
PC
導電性PE
用紙
Mylar A
Mylar B
Paper
Metal Plate
Metal Plate
Paper
Mylar B
Mylar A
ttach the Mylar as shown in the photo above if
the “Cover: 1
st
Transfer Ass’y” includes a Mylar.
If 2pcs are included, attach both pcs.
Cover: 1
s
Transfer Ass’y
Mylar for adjustment