Technical Bulletin PAGE: 1/1
Model: Aries-P1.5/C1.5 Date: 16-Nov-10 No.: RM077010
Subject: Manual Correction for Aries-P1.5/C1.5 Air Separator
SP
Prepared by: Hidetoshi Kawamura
From: PPBG Service Planning Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other ( ) Tier 2
The Service Manual for Aries-P1.5/C1.5 was corrected
On pages from 355 to 357
Air Separator Setting (From SP 1-901-101 to SP 1-901-124), in the service manual, it is
written as following.
0: No air blowing
1: Normal air blowing
2: Low air blowing
Correction
Air Separator Setting (From SP 1-901-101 to SP 1-901-124)
0: No air blowing
1: Normal air blowing
Setting “2” is no longer used; therefore, please do not use setting “2”
If “2” is used, air will not blow from the air separator.