EasyManua.ls Logo

Ricoh SP 3710DN - Page 245

Ricoh SP 3710DN
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.Detailed Descriptions
233
Fusing Temperature Control
Callout
Item
A
Warm up mode
B
Standby mode
C
Print mode
D
Standby mode
E
Energy saver mode 1
F
Energy saver mode 2
When the main switch is turned on, the CPU turns on the fusing lamp using the soft start process. (The
soft start process prevents the room lights from flickering.) The lamp stays on until the thermistor
detects the standby temperature. Then the CPU maintains this temperature using on-off control. To start
printing, the CPU raises the temperature to the printing temperature.
The fusing temperature for each condition is as follows:
Condition
Temperature (degree)
Standby
155
Energy saver mode 1
(Low power)
120
Energy saver mode 2
Ambient temperature
Plain paper
175
Thick 1 paper
185
Thick 2 paper
185
Thin paper
170
Envelopes
185
Postcards
185
Recycled
170
The fusing temperature for each condition (except “Energy saver mode 2”) can be adjusted with “Fusing

Table of Contents