Chapter
10
Waveform Record
RIGOL
DS
2
000E
User
’
s Guide
10
-5
Fi
gur
e
10-1
Reco
r
d Constant On
3.
Press
R
UN
/S
TOP
to stop the record.
4.
Analyze the
wa
vef
orm rec
orded usi
ng wa
vef
orm an
alysis an
d as sh
own in
the
f
igure below
,
the runt pulse
s are captured.
Fi
gur
e
10-2
Analyze
the w
a
veform
reco
rded
202
204
Table of Contents
Guaranty and Declaration
3
Safety Requirement
4
Safety Terms and Symbols
7
Allgemeine Sicherheits Informationen
8
Sicherheits Begriffe und Symbole
11
Measurement Category
12
Ventilation Requirement
13
Working Environment
14
Care and Cleaning
16
Environmental Considerations
17
DS2000E Series Overview
18
Document Overview
20
Table of Contents
23
Chapter 1 Quick Start
29
General Inspection
30
Appearance and Dimensions
31
To Prepare the Oscilloscope for Use
32
To Adjust the Supporting Legs
32
To Connect to AC Power
32
Turn-On Checkout
33
To Connect the Probe
33
Function Inspection
34
Probe Compensation
35
Front Panel Overview
36
Rear Panel Overview
38
Front Panel Function Overview
40
Vertical
40
Horizontal
41
Trigger
42
Clear
43
Run/Stop
43
Single
43
Auto
43
Multi-Function Knob
44
Navigation Knob
44
Function Keys
45
Record
46
Print
46
User Interface
47
To Use the Security Lock
51
To Use the Built-In Help System
52
Chapter 2 To Set the Vertical System
53
To Enable the Analog Channel
54
Channel Coupling
55
Bandwidth Limit
55
Probe Ratio
56
Input Impedance
57
Waveform Invert
57
Vertical Scale
58
Vertical Expansion
59
Amplitude Unit
59
Channel Label
59
Delay Calibration
61
Chapter 3 To Set the Horizontal System
63
Delayed Sweep
64
Time Base Mode
66
Y-T Mode
66
X-Y Mode
66
Roll Mode
69
Horizontal Scale
70
Horizontal Reference
71
Chapter 4 To Set the Sample System
73
Acquisition Mode
74
Normal
74
Average
74
Peak Detect
76
High Resolution
76
Sample Mode
77
Sample Rate
78
Memory Depth
80
Anti-Aliasing
81
Chapter 5 To Trigger the Oscilloscope
83
Trigger Source
84
Trigger Mode
85
Trigger Coupling
86
Trigger Holdoff
87
Noise Rejection
88
Trigger Type
89
Edge Trigger
90
Pulse Trigger
92
Runt Trigger
94
Windows Trigger (Option)
97
Nth Edge Trigger (Option)
99
Slope Trigger
101
Video Trigger (HDTV Option)
104
Pattern Trigger
107
Delay Trigger (Option)
109
Timeout Trigger (Option)
112
Duration Trigger (Option)
114
Setup/Hold Trigger
115
RS232 Trigger
117
I2C Trigger
119
SPI Trigger
123
USB Trigger (Option)
125
CAN Trigger (Option)
127
Trigger Output Connector
130
Chapter 6 MATH and Measurements
131
Math Operation
132
Addition
132
Subtraction
132
Multiplication
133
Division
133
Fft
134
Digital Filter
137
Logic Operation
139
Advanced Operation
140
MATH Label
143
Auto Measurement
144
Quick Measurement after AUTO
144
One-Key Measurement of 29 Parameters
146
Frequency Counter Measurement
152
Measurement Setting
153
To Clear the Measurement
156
All Measurement
157
Statistic Function
158
Measurement History
158
Cursor Measurement
159
Manual Mode
160
Track Mode
164
Auto Mode
166
X-Y Mode
167
Chapter 7 Protocol Decoding
169
Parallel Decoding
170
RS232 Decoding (Option)
173
I2C Decoding (Option)
178
SPI Decoding (Option)
182
CAN Decoding (Option)
185
Chapter 8 Reference Waveform
189
To Enable REF Function
190
To Set the Color
190
To Select REF Source
190
To Save REF Waveform
191
To Adjust REF Waveform Display
191
To Export to Internal or External Memory
191
To Import from Internal or External Memory
192
Chapter 9 Pass/Fail Test
193
To Enable Pass/Fail Test
194
To Select Source
194
Mask Range
194
To Set Test Results Output Type
196
To Save the Test Mask
197
To Load the Test Mask
197
Chapter 10 Waveform Record
199
Waveform Record
200
Record Constant on
202
Waveform Playback
204
Waveform Analysis
206
Analysis Based on Trace
210
Analysis Based on Pass/Fail Mask
211
Chapter 11 Display Control
213
To Select the Display Type
214
To Set the Persistence Time
214
To Set the Waveform Intensity
216
To Set the Screen Grid
216
To Set the Grid Brightness
216
To Set the Menu Display
216
Chapter 12 Store and Recall
217
Storage System
218
Storage Type
219
Internal Storage and Recall
221
External Storage and Recall
223
Disk Management
225
To Select File Type
225
To Create a New File or Folder
226
To Delete a File or Folder
229
To Rename a File or Folder
230
To Clear the Local Memory
230
Factory
231
Chapter 13 System Function Setting
239
Remote Interface Configuration
240
LAN Setting
240
USB Device
245
GPIB Address
245
System-Related
246
Sound
246
Language
246
System Information
247
Power-Off Recall
247
System Time
248
Screen
249
Self-Calibration
250
Print Setting
251
Power Status
253
Aux Output
254
Option Management
255
Auto Setting
257
Chapter 14 Remote Control
259
Remote Control Via USB
260
Remote Control Via LAN
264
Remote Control Via GPIB
266
Chapter 15 Troubleshooting
269
Chapter 16 Specifications
271
Chapter 17 Appendix
279
Appendix A: Accessories and Options
279
Appendix B: Warranty
280
Index
281
Other manuals for Rigol DS2000E Series
Quick Guide
37 pages
Programming Guide
365 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?
Ask a question
Rigol DS2000E Series Specifications
General
Brand
Rigol
Model
DS2000E Series
Category
Test Equipment
Language
English
Related product manuals
Rigol DS2302A
335 pages
Rigol DS4024
393 pages
Rigol DS1054
66 pages
Rigol DS7024
374 pages
Rigol DS6104
298 pages
Rigol DS1104Z
38 pages
Rigol DS1204B
172 pages
Rigol DS1052E
166 pages
Rigol DS1054Z
268 pages
Rigol DS1052D
166 pages
Rigol DS4024E
329 pages
Rigol DS1102/4B
164 pages