Chapter 10 Waveform Record RIGOL
DS2000E User’s Guide 10-13
Analysis Based on Pass/Fail Mask
Press Analyze and select "Pass/Fail". Then, set the templet used in analysis based
on Pass/Fail mask through the method below.
Press Range to open the mask range setting menu. Please refer to the introduction
in "
Mask Range" to create the test mask used in waveform analysis.
Besides, you can store the current test mask in "*.pf" format into the internal
memory or external USB storage device or load the test mask file stored in the
internal memory or external USB storage device into the instrument. Press Save to
enter the file store interface. Store the test mask file to internal or external memory
by referring to the introduction in "Store and Recall". Press Load to enter the file
recall interface. Load the test mask into the instrument by referring to the
introduction in "Store and Recall".