Chapter 10 Waveform Record RIGOL
DS2000E Users Guide 10-11
default is the first frame.
End Frame: press this key to set the end frame of waveform analysis (refer
to the setting method of the current frame mentioned above) and the
default is the last frame.
Threshold: press this key to set the threshold of waveform analysis and the
range is from 1% to 99%. The threshold is used to judge whether the frame
is an error frame. A frame is recognize as an error one if the (relative)
difference value between the frame and the templet is equal to or larger
than the threshold currently set.
9. Time Tag
The time tag is used to display the absolute recording time of each frame of the
waveform currently recorded. Press Time Tag to enable or disable the time tag
function. When it is enabled, the time tag information is displayed at the upper
right corner of the screen as shown in the figure below.
T
0
:
display the absolute starting time of the waveform record.
T: display the recording time deviation of the current waveform relative to the
first frame of waveform.

Table of Contents

Other manuals for Rigol DS2000E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?

Rigol DS2000E Series Specifications

General IconGeneral
BrandRigol
ModelDS2000E Series
CategoryTest Equipment
LanguageEnglish

Related product manuals