EasyManua.ls Logo

Rinstrum C530 - Page 93

Rinstrum C530
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Name Address Type R W Description
Setpoint Jog Off A40C
H
uint32 A A Duration of setpoint jog off time in ms.
Setpoint Jog On A40D
H
uint32 A A Duration of setpoint jog on time in ms.
Setpoint 1 Timing A410
H
uint8 A A Setpoint 1 timing:
0 is level
1 is edge
2 is latch
3 is pulse.
Setpoint 1 Reset A411
H
uint8 A A Setpoint 1 rest:
0 is none
1 is reset A
2 is reset B.
Setpoint Jog Set A412
H
uint8 A A Number of jogs in a set.
Setpoint Max Jog Set A413
H
uint8 A A Maximum number of jog sets. Set to 0 for
unlimited sets.
Setpoint 2 type A421
H
uint8 A A Set setpoint 2 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
Setpoint 2 lock A422
H
uint8 A A Set setpoint 2 lock:
0 is off
1 is on.
Setpoint 2 logic A423
H
uint8 A A Set setpoint 2 logic:
0 is high
1 is low.
Setpoint 2 alarm A424
H
uint8 A A Set setpoint 2 alarm:
0 is none
1 is single beep
2 is double beep
3 is continuous beeping
4 is flash the display.
Setpoint 2 source A426
H
uint8 A A Set setpoint 2 source:
0 is gross weight
1 is net weight.
Setpoint 2 Target A428
H
int32 A A Set setpoint 2 target.
Setpoint 2 Hysteresis A429
H
int32 A A Set setpoint 2 hysteresis.
Setpoint 2 in flight A42A
H
int32 A A Set setpoint 2 in flight.
Setpoint 2 Timing A430
H
uint8 A A Setpoint 2 timing:
0 is level
1 is edge
2 is latch
3 is pulse.
88 C500-600-2.0.3

Table of Contents

Other manuals for Rinstrum C530

Related product manuals