22 ProSYS User's Manual
3)
THE JONESES
HOME: EXIT = 0:45
THE JONESES
HOME: EXIT = 0:45
If required, leave the premises and close the
door.
During the Exit Delay time period, the keypad
beeps, the Arm/
LED flashes, and the
Bypass/
LED lights, indicating that the
interior zones are being bypassed.
THE JONESES
AT HOME ARMED
THE JONESES
AT HOME ARMED
When the Exit Delay time period is up, the
Arm/
LED lights steadily.
Partition Arming
One of the ProSYS advantages is its ability to divide any system into a
number of partitions. Each partition may be viewed as a separate security
system, each of which can be armed and disarmed individually regardless
of the condition of the other.
Partitions can be armed/disarmed one at a time, or all at once, and can be
Stay or Away armed.
Keypads and Partitions - Each keypad is assigned to different partition(s).
The Grand Master and the Manager (with access to all partitions) can use
any keypad to access any partition. Other users can use only designated
keypads.
Common Zones - Partitioned systems have to share common zones. For
example, a shared front door to two family houses must be available to
both families and is therefore shared between them.
A common zone(s) is armed only if all partitions sharing the zone(s) are
armed. The common zone(s) is disarmed if any of the partitions, to which
the zone(s) is assigned, are disarmed.
If the system is defined to work in Area mode, the common zone will be
armed if any partition sharing the zone is armed. The common zone will be
disarmed if all the partitions sharing the zone are disarmed.