35
2) Not measure the backsight point
STEP
OPERATION
DISPLAY
c.
If not measuring the backsight point,
press [ENT] directly.
[ENT]
Input BS PT
BS:
3
1
HI:
0.000m
CD:
Stac
d.
Sight the BS point in F1, and press [ENT]
to finish setting.
If the horizontal circle is on Face-2,
screen would display Turn to F1. As
show in the right graph. Rotate the
telescope and alidade, and sight the BS
point in Face-1.
Stn Setup
1/2
AZ:
20°0000”
HD:
SD:
* Obs.BS [MSR]/[ENT]
F2
e.
Procedure records the station and raw
data to current job and finish setting up
station. Screen returns to basic
measurement screen. AZ item displays
the result of determining Backsight
azimuth.
Display
2/5
AZ#
20°0000”
HD#
SD#
PT:1
HT:
1.000m
4.1.2 Sight the Backsight by Entering the Azimuth Angle

Table of Contents