EasyManua.ls Logo

Rlide R2 Series - Checking and Resetting Backsight Direction

Default Icon
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
b.
If no station is set before, program shows
the right graph.
!
Invalid STN
* Press any key
c.
Press any key to return to “Stn Setup”
menu, select one method to set station.
Stn Setup
1. Known
2. Rese
3. QuickStn
4. Z Coord
5. BS Check
d.
After the program record the station,
Input level point, and press [ENT]. 1)
Enter point
name
[ENT]
Input PT
PT:
1
HI:
1.800m
CD:
List
Stac
e.
Enter height of target prism, and press
[ENT].
Enter height of
target prism
[ENT]
Input PT
PT:
1
1
HI:
1.800m
CD:
List
Stac
f.
Sight the center of prism, press [MSR1]
or [MSR2] to start survey.
If the horizontal circle is on Face-2,
screen would display Turn to F1. Rotate
the telescope and alidade, and sight the
BS point in Face-1.
Sight the target
[MSR 1]/
[MSR 2]
Level point
HA#
355°5159
VD#
HD#
* Sight Press [MSR]
F2
g.
The system finishes the measurement
and displays the result.
Level point
HA#
355°5159
VD#
-0.053m
HD#
1.982m
* Press [ENT]
F2