Limitations in dimensions: None
Maximum speed: 3000 rpm
The speed can be freely changed during the cut. A stop can be made at any time by pressing
the STOP button.
There are three possible variants:
1. ZP = 0 and XP = 0 so there are no endpoints at all specied, in which case the movement
after the START signal goes to Z 0,00 after a safety query and then in the -X direction until the
STOP key is pressed. START-Stop operation is possible while the vehicle is in motion. Only when
the STOP button is pressed does the movement abort, after which X and Z are reset to the stop
position.
2. ZP = 0 XP < 0, therefore only one end position for Z is indicated, no depth. Here the move-
ment goes directly after the START signal WITHOUT safety query to Z 0,00 and then in -X-direc-
tion to the end point X P. Then a reset to Z 0,2 and back to X 0,00 takes place, then the position
for X and Z changes to hold position.
3. ZP < 0 and XP < 0, so the values for depth and radius are specied. The cutting process is
fully automatic in several passes. After the START signal, the controller rst displays all the data
for the individual passes in an overview and then starts after a new start command. Here you
can also abort by pressing the STOP key. The same applies to the number of passes as written
for „outside turning“.
65