= 0.5 m long gate leaf; = 1 m long gate leaf; = 1.5 m long gate leaf; = 2 m long gate leaf;
!KEXIPIEJƶQMRPIRKXL
-JXLMWJYRGXMSRMWIREFPIHXLIXSVUYIETTPMIHMWVIHYGIHHYVMRKXLIƼREPTEVXSJXLIKEXIXVEZIPXSVIHYGI
gate vibration when it reaches the stop.
3RMRWXEPPEXMSRW[MXLERIPIGXVMGPSGOXLIXSVUYIETTPMIHMWMRGVIEWIHHYVMRKXLIƼREPTEVXSJXLIGPSWMRK
XVEZIPXSIRWYVIXLEXXLIPSGOPEXGLIWGSVVIGXP]3RMRWXEPPEXMSRW[MXLRSIPIGXVMGPSGOXLIXSVUYIETTPMIHMW
VIHYGIHHYVMRKXLIƼREPTEVXSJXLIKEXIXVEZIPXSVIHYGIKEXIZMFVEXMSR
2&TEVEQIXIVZMWMFPISRP]MJIRGSHIVMWIREFPIH .
Enable electric lock release reverse impulse
Disabled.
)REFPIH%XXLIWXEVXSJIEGLSTIRMRKQERSIYZVIXLIGSRXVSPYRMXETTPMIWEFVMIJGPSWMRKJSVGIWIXXEFPI
from 1 to 4 s) to release the electric lock.
Enabling the electric lock release reverse impulse function automatically enables parameters
(electric lock lead time = 1 s) and (electric lock activation time = 3 s).
Set deceleration during opening/closure
Disabled.
1IHMYQHIGIPIVEXMSR2&QE\MQYQWIXXEFPIZEPYIJSVTSPIQSXSVW
1E\MQYQHIGIPIVEXMSR-14368%28(323897)TSPIQSXSVW
Set obstacle detection sensitivity during manoeuvres
The gate reverses immediately when an obstacle is detected during an opening or closing manoeuvre.
2&WIXEZEPYIFIPS[ for 6 pole motors.
Set obstacle detection sensitivity during deceleration
The gate reverses immediately when an obstacle is detected during opening or closing deceleration.
2&WIXEZEPYIFIPS[ for 6 pole motors.
From 1% to 99%.
= minimum sensitivity ... = maximum sensitivity.
Setting number of automatic closure attempts after activation of sensing edge
or obstacle detection (crush protection)
No automatic closure attempts.
From 1 to 3 automatic closure attempts.
We recommend setting a value equal to or lower than the value set for parameter $.
Automatic closure is only performed if the gate is completely open.
Setting photocell mode during gate opening (FT1)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening
when the photocell is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell
is cleared.
Setting photocell mode during gate closing (FT1)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate closure.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed closing
when the photocell is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate opens when the photocell is
cleared.