EasyManua.ls Logo

Rohde & Schwarz FSW Series - Page 98

Rohde & Schwarz FSW Series
371 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
R&S
®
FSW-K7
98User Manual 1173.9240.02 ─ 17
RF Power ← Trigger Source
Defines triggering of the measurement via signals which are outside the displayed
measurement range.
For this purpose the instrument uses a level detector at the first intermediate fre-
quency. The input signal must be in the frequency range between 500 MHz and
8 GHz.
The resulting trigger level at the RF input depends on the RF attenuation and preampli-
fication. For details on available trigger levels see the data sheet.
Note: If the input signal contains frequencies outside of this range (e.g. for fullspan
measurements), the sweep may be aborted and a message indicating the allowed
input frequencies is displayed in the status bar.
A "Trigger Offset", "Trigger Polarity" and "Trigger Holdoff" (to improve the trigger stabil-
ity) can be defined for the RF trigger, but no "Hysteresis".
This trigger source is not available for input from the Digital Baseband Interface
(R&S FSW-B17) or the Analog Baseband Interface (R&S FSW-B71). If the trigger
source "RF Power" is selected and digital I/Q or analog baseband input is activated,
the trigger source is automatically switched to "Free Run".
Remote command:
TRIG:SOUR RFP, see TRIGger[:SEQuence]:SOURce on page 250
Power Sensor ← Trigger Source
Uses an external power sensor as a trigger source. This option is only available if a
power sensor is connected and configured.
Note: For R&S power sensors, the "Gate Mode" Lvl is not supported. The signal sent
by these sensors merely reflects the instant the level is first exceeded, rather than a
time period. However, only time periods can be used for gating in level mode. Thus,
the trigger impulse from the sensors is not long enough for a fully gated measurement;
the measurement cannot be completed.
Remote command:
TRIG:SOUR PSE, see TRIGger[:SEQuence]:SOURce on page 250
Trigger Level
Defines the trigger level for the specified trigger source.
For details on supported trigger levels, see the data sheet.
Remote command:
TRIGger[:SEQuence]:LEVel:IFPower on page 247
TRIGger[:SEQuence]:LEVel:IQPower on page 248
TRIGger[:SEQuence]:LEVel[:EXTernal<port>] on page 247
For analog baseband (B71) or digital baseband (B17) input only:
TRIGger[:SEQuence]:LEVel:RFPower on page 248
TRIGger[:SEQuence]:LEVel:AM:RELative on page 248
TRIGger[:SEQuence]:LEVel:AM[:ABSolute] on page 249
TRIGger[:SEQuence]:LEVel:FM on page 249
TRIGger[:SEQuence]:LEVel:PM on page 249
Trigger Configuration

Table of Contents

Other manuals for Rohde & Schwarz FSW Series

Related product manuals