Remote Control - Commands
NRP2
250User Manual 1173.9140.02 ─ 07
MEMory:TABLe:DATA?.................................................................................................. 252
MEMory:TABLe:DATA:POINts?
.......................................................................................253
MEMory:TABLe:FREQuency...........................................................................................253
MEMory:TABLe:FREQuency:POINts?..............................................................................253
MEMory:TABLe:GAIN[:MAGNitude]................................................................................. 253
MEMory:TABLe:GAIN:POINts?....................................................................................... 254
MEMory:TABLe:MAP..................................................................................................... 254
MEMory:TABLe:MOVE...................................................................................................254
MEMory:TABLe:RESet................................................................................................... 254
MEMory:TABLe:SELect.................................................................................................. 254
MEMory:CATalog[:ALL]?
Lists the names of all stored device states and correction tables. The length of the
response depends on how many device states and tables are stored.
Return values:
<NR1>, <NR1>
{,"<string>"}
The first two values denote the length in bytes of the occupied
RAM and of the RAM still available for storing states and tables.
These values are followed by a string for each stored state and
then for each stored table; this string again consists of two
strings and a numeric value:
<string>,
<type>,
<NR1>
<string> gives the name of the stored data item, <type> the
type (TABL or STAT) and <NR1> the length of the data item in
bytes.
Example: The response to query MEM:CAT? could be:
956,
99044,"REFL,
STAT,408","NRPZ21,TABL,432",
"SPLITTER1,TABL,116"
Usage: Query only
MEMory:CATalog:STATe?
Only gives a list of stored device states and is otherwise identical with
MEMory:CATalog[:ALL]?.
Usage: Query only
MEMory:CATalog:TABLe?
Only gives a list of stored correction tables and is otherwise identical with
MEMory:CATalog[:ALL]?.
Usage: Query only
MEMory:CLEar[:NAME] <name>
Clears the content of the correction table or the stored device state with the designa-
tion <name>. The table is maintained but does not contain entries.
MEMory