Remote Control - Commands
NRP2
224User Manual 1173.9140.02 ─ 07
MEASurement<[1]..8>:ARRay[:POWer][:AVG]:REFLection
MEASurement<[1]..8>:ARRay[:POWer][:AVG]:RLOSs
(<buffered_size>),
[<expected_value>[,<resolution>]] [,<source_list>]
MEASurement commands for measurement mode ContAv with buffering.
MEASurement<[1]..8>:XTIMe[:POWer]
MEASurement<[1]..8>:XTIMe[:POWer]:RATio (<scope_size>), <capture_time>
[,<source_list>]
MEASurement commands for measurement mode Trace.
MEASurement<[1]..8>:STATistics:CCDF
MEASurement<[1]..8>:STATistics:PDF (<statistics_size>), <capture_time>
[,<source_list>]
MEASurement commands for measurement mode Statistics.
6.5 CALCulate (Configuration of Calculate Blocks)
The calculate blocks calculating the measurement results from the sensor data are
configured with the CALCulate command. Eight blocks are available, each with two
input channels (primary and secondary channel). The available sensors (1 to 4,
depending on device configuration and connected sensors) can be assigned to the
channels. With the aid of a selectable function (CALC:MATH), the channels can be pro-
cessed together.
Suffix <1..8>behind the CALCulate key word denotes the CALCulate block. Each
CALCulate block is assigned a measurement window. The R&S R&S NRP2 can dis-
play up to four windows with measurement results.
In the digital "Dig" and digital/analog
"D&A" mode CALCulate blocks 1 to 4 are asso-
ciated with the windows 1 to 4. In the graphical "Graph" mode, the CALCulate blocks
1 to 8 are associated with the measurement windows and the traces as follows:
Calculate block Window Trace
1...4 1...4 1
5...8 1...4 2
Suffix <1|2> behind the FEED key word word assigns a sensor to the primary or secon-
dary channel.
CALCulate<[1]..8>:COUNt:DATA?...................................................................................225
CALCulate<[1]..8>:
DATA?.............................................................................................. 225
CALCulate<[1]..8>:EXTRemes:RESet..............................................................................226
CALCulate<[1]..8>:FEED<[1]|2>...................................................................................... 226
CALCulate<[1]..8>:LIMit:BEEP........................................................................................ 227
CALCulate<[1]..8>:LIMit:CLEar[:IMMediate]......................................................................227
CALCulate (Configuration of Calculate Blocks)