Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
98
Specifications and Reference Data
PlantWeb enhanced measurement functionality
(27)
D 1-7
H01 FOUNDATION Fieldbus fully compensated mass flow block
Cold temperature
(28)
BRR -60 °F (-51 °C) Cold temperature start-up
Alarm limit
(22)(29)
C4 NAMUR alarm and saturation levels, high alarm
C5 NAMUR alarm and saturation levels, low alarm
C6 Custom alarm and saturation levels, high alarm
C7 Custom alarm and saturation levels, low alarm
C8 Low alarm (standard Rosemount alarm and saturation levels)
Hardware adjustments and ground screw
D1
(22)(29)(30)
Hardware adjustments (zero, span, alarm, security)
D4
(31)
External ground screw assembly
DA
(22)(29)(30)
Hardware adjustments (zero, span, alarm, security) and external ground screw
assembly
Conduit plug
DO 316 SST conduit plug
Conduit electrical connector
(32)
GE M12, 4-pin, Male Connector (eurofast
®
)
GM A size Mini, 4-pin, Male Connector (minifast
®
)
Typical model number: 3051SFA D L 060 D C H P S 2 T1 0 0 0 3 2A A 1A 3
1. See the DP Flow Product Data Sheet (document number 00813-0100-4485) for Pipe I.D. table.
2. Provide the “A” dimension for Flanged (page 181), Flange-Lok (page 179), and Threaded Flo-Tap (page 185) models. Provide the “B” dimension for Flange
Flo-Tap models (page 183).
3. Available in remote mount applications only.
4. The cage nipple is constructed of 304SST.
5. Temperature Measurement Option code T or R is required for Measurement Type codes 1, 3, 5, and 7.
6. Required for Measurement Type codes 2, 4, 6, and D.
7. Required for Measurement Type codes 3, 4, 7, and D.
8. For Measurement Type 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig (-0,98
to 137,9 bar).
9. Only intrinsically safe approval codes apply.
10. Only available with Measurement Types D and 6.
11. Only available with output code X.
12. Available with output code A only.
13. For detailed specifications see“Performance specifications” on page 109.
14. Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
15. Long-life Power Module must be shipped separately, order Power Module 701PBKKF.
16. Applies to assembled flowmeter only, mounting not tested.
17. Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
18. Not available with Transmitter Connection Platform 6.
Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3051SFC_A and is the answer not in the manual?

Rosemount 3051SFC_A Specifications

General IconGeneral
BrandRosemount
Model3051SFC_A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals