Appendix B Product Certifications
Hazardous Locations Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 213
Rosemount
®
3051SFA and 3051SFC_A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 213
Rosemount 3051CFA and 3051CFC_A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 218
Rosemount 2051CFA and 2051CFC_A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 224
Installation Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 229
B.1 Hazardous Locations
Installations
The flowmeter is designed with explosion-proof housings and
circuitry suitable for intrinsically safe and non-incendive
operation. Each flowmeter is clearly marked with a tag
indicating the approvals. To maintain certified ratings for
installed transmitters, install in accordance with all applicable
installation codes and approval drawings. Verify that the
operating atmosphere of the transmitter is consistent with
the appropriate hazardous locations certifications. Both
transmitter covers must be fully engaged to meet explosion
proof requirements.
B.2 Rosemount
®
3051SFA and
3051SFC_A
Rev 1.2
B.2.1 European Directive Information
A copy of the EC Declaration of Conformity can be found at
the end of the Quick Start Guide. The most recent revision of
the EC Declaration of Conformity can be found at
www.rosemount.com.
B.2.2 Ordinary Location Certification
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a nationally
recognized test laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).As
standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical,
and fire protection requirements by FM, a nationally
recognized testing laboratory (NRTL) as accredited by the
Federal Occupational Safety and Health Administration
(OSHA).
B.2.3 Installing Equipment in North America
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in
Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information is
clearly defined in the respective codes.
USA
E5 FM Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 3008216
Standards: FM Class 3600 - 2011, FM Class 3615 - 2006,
FM Class 3616 - 2011, FM Class 3810 - 2005,
ANSI/NEMA 250 - 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP
E, F, G; CL III; T5(-50 °C
T
a
+85 °C);
Factory Sealed; Type 4X
I5 FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 3031960
Standards: FM Class 3600 -2011, FM Class 3610 - 2007,
FM Class 3611 - 2004, FM Class 3616 - 2006,
FM Class 3810 - 2005, NEMA 250 - 1991
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E,
F, G; Class III; Class 1, Zone 0 AEx ia IIC T4;
NI CL 1, DIV 2, GP A, B, C, D;
T4(-50 °C
T
a
+70 °C); when connected per
Rosemount drawing 03151-1206; Type 4X
Note
Transmitters marked with NI CL 1, DIV 2 can be installed
in Division 2 locations using general Division 2 wiring
methods or Nonincendive Field Wiring (NIFW). See
Drawing 03151-1206.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3051SFC_A and is the answer not in the manual?

Rosemount 3051SFC_A Specifications

General IconGeneral
BrandRosemount
Model3051SFC_A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals