Reference Manual
00809-0100-4809, Rev DA
Appendix B: Product Certifications
September 2015
229
Product Certifications
5. The cables between this product and associated
apparatus should be shielded cables (the cables must
have insulated shield). The shielded cable has to be
grounded reliably in a non-hazardous area.
6. End users are not permitted to change any internal
components, and needs to settle the problem in
conjunction with the manufacturer to avoid damage to
the product.
7. During installation, use and maintenance of this
product, observe the following standards:
GB3836.13-1997, GB3836.15-2000, GB3836.16-2006,
GB50257-1996
Japan
E4 Japan Flameproof
Certificate: TC20598, TC20599, TC20602, TC20603
[HART]; TC20600, TC20601, TC20604,
TC20605 [Fieldbus]
Markings: Ex d IIC T5
Combinations
K1 Combination of E1, I1, N1, and ND
K2 Combination of E2 and I2
K5 Combination of E5 and I5
K6 Combination of E6 and I6
K7 Combination of E7, I7, and N7
KB Combination of K5 and K6
KD Combination of K1, K5, and K6
Additional Certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate: 09-HS446883B-3-PDA
Intended Use: Marine & Offshore Applications –
Measurement of either Gauge or Absolute
Pressure for Liquid, Gas, and Vapor.
ABS Rules: 2013 Steel Vessels Rules 1-1-4/7.7,
1-1-Appendix 3, 4-8-3/1.7, 4-8-3/13.1
SBV Bureau Veritas (BV) Type Approval
Certificate: 23157/A2 BV
BV Rules: Bureau Veritas Rules for the Classification of
Steel Ships
Application: Class notations: AUT-UMS, AUT-CCS,
AUT-PORT and AUT-IMS; Pressure
transmitter type 2051 cannot be installed
on diesel engines
SDN Det Norske Veritas (DNV) Type Approval
Certificate: A-13245
Intended Use: Det Norske Veritas’ Rules for Classification
of Ships, High Speed & Light Craft Det
Norske Veritas’ Offshore Standards
Application:
SLL Lloyds Register (LR) Type Approval
Certificate: 11/60002
Application: Environmental categories ENV1, ENV2,
ENV3 and ENV5
B.5 Installation Drawings
B.5.1 Rosemount 3051SFA ProBar Flowmeter
Rosemount Drawing 03031-1019, 13 Sheets:
Factory Mutual (FM) Installation Drawing.
Rosemount Drawing 03031-1024, 9 Sheets:
Canadian Standards Association (CSA) Installation Drawing.
B.5.2 Rosemount 3051SFC_A Flowmeter
Rosemount Drawing 00405-1001, 7 sheets:
Factory Mutual (FM) Installation Drawing.
Important
Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any of the
other labeled approval types. To ensure this, the
approval label should be permanently marked to
distinguish the used from the unused approval type(s).
Location classes
Typ e 2051
Temperature D
Humidity B
Vibration A
EMC B
Enclosure D