EasyManuals Logo

Rosemount 3051SFC_A User Manual

Rosemount 3051SFC_A
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #227 background imageLoading...
Page #227 background image
Reference Manual
00809-0100-4809, Rev DA
Appendix B: Product Certifications
September 2015
219
Product Certifications
I5 USA Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 1Q4A4.AX
Standards: FM Class 3600 – 2011,
FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E,
F, G; Class III; DIV 1 when connected per
Rosemount drawing 03031-1019; NI CL 1,
DIV 2, GP A, B, C, D; T4(-50 °C
T
a
+70 °C)
[HART], T5(-50 °C
T
a
+40 °C) [HART];
T4(-50 °C
T
a
+60 °C)
[Fieldbus/PROFIBUS]; Type 4x
Special Conditions for Safe Use (X):
1. The Model 3051 transmitter housing contains
aluminum and is considered a potential risk of ignition
by impact or friction. Care must be taken into account
during installation and use to prevent impact and
friction.
2. The Model 3051 transmitter with the transient terminal
block (Option code T1) will not pass the 500Vrms
dielectric strength test and this must be taken into
account during installation
IE USA FISCO
Certificate: 1Q4A4.AX
Standards: FM Class 3600 – 2011,
FM Class 3610 – 2010,
FM Class 3611 – 2004, FM Class 3810 – 2005
Markings: IS CL I, DIV 1, GP A, B, C, D when connected
per Rosemount drawing 03031-1019
(-50 °C
T
a
+60 °C); Type 4x
Special Conditions for Safe Use (X):
1. The Model 3051 transmitter housing contains
aluminum and is considered a potential risk of ignition
by impact or friction. Care must be taken into account
during installation and use to prevent impact and
friction.
2. The Model 3051 transmitter with the transient terminal
block (Option code T1) will not pass the 500Vrms
dielectric strength test and this must be taken into
account during installation
C6 Canada Explosionproof, Dust-Ignitionproof, Intrinsic
Safety and Nonincendive
Certificate: 1053834
Standards: ANSI/ISA 12.27.01-2003,
CSA Std. C22.2 No. 30 -M1986,
CSA Std. C22.2 No.142-M1987,
CSA Std. C22.2. No.157-92,
CSA Std. C22.2 No. 213 - M1987
Markings: Explosionproof for Class I, Division 1, Groups
B, C and D; Suitable for Class I, Zone 1,
Group IIB+H2, T5; Dust-Ignitionproof Class
II, Division 1, Groups E, F, G; Class III Division
1; Intrinsically Safe Class I, Division 1 Groups
A, B, C, D when connected in accordance
with Rosemount drawing 03031-1024,
Temperature Code T3C; Suitable for Class I,
Zone 0; Class I Division 2 Groups A, B, C and
D, T5; Suitable for Class I Zone 2, Group IIC;
Type 4X; Factory Sealed; Single Seal (See
drawing 03031-1053)
E6 Canada Explosionproof, Dust-Ignitionproof and
Division 2
Certificate: 1053834
Standards: ANSI/ISA 12.27.01-2003,
CSA Std. C22.2 No. 30 -M1986,
CSA Std. C22.2 No.142-M1987,
CSA Std. C22.2 No. 213 - M1987
Markings: Explosionproof Class I, Division 1, Groups B,
C and D; Suitable for Class I, Zone 1, Group
IIB+H2, T5; Dust-Ignitionproof for Class II
and Class III, Division 1, Groups E, F and G;
Class I, Division 2, Groups A, B, C and D;
Suitable for Class I Zone 2, Group IIC; Type
4X; Factory Sealed; Single Seal (See drawing
03031-1053)
Europe
E8 ATEX Flameproof and Dust
Certificate: KEMA00ATEX2013X; Baseefa11ATEX0275X
Standards: EN60079-0:2012 + A11:2013,
EN60079-1:2007, EN60079-26:2007,
EN60079-31:2009
Markings: II 1/2 G Ex d IIC T6/T5 Ga/Gb,
T6(-50 °C
T
a
+65 °C),
T5(-50 °C
T
a
+80 °C);
II 1 D Ex ta IIIC T95 °C T
500
105 °C Da
(-20°C
T
a
+85°C)
Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will
be subjected. The manufacturer’s instructions for
installation and maintenance shall be followed in detail
to assure safety during its expected lifetime.
2. For information on the dimensions of the flameproof
joints the manufacturer shall be contacted.
3. Some variants of the equipment have reduced markings
on the nameplate. Refer to the Certificate for full
equipment marking.
Table 1. Process Temperature
Temperature class Process temperature
T6 -50 °C to +65 °C
T5 -50 °C to +80 °C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3051SFC_A and is the answer not in the manual?

Rosemount 3051SFC_A Specifications

General IconGeneral
BrandRosemount
Model3051SFC_A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals