Effectivity 912/914 Series
Edition 1 / Rev. 0
page 15
May 01/2007
d02623
73-00-00
BRP-Rotax
Maintenance Manual
2.9) Handling of fuel
Use only clean gasoline of a registered brand.
Unleaded fuels contain alcohol. Alcohol binds up to 50 % of its own volume in
water. Water enters the system mainly in the form of condensation. For this
reason, avoid extreme differences in temperature, long period storage, direct
sun and plastic containers. When handling fuel, observe the directives without
fail.
When refuelling, observe the relevant regulations of the competent aviation
authorities.
â–² WARNING: Before refueling, switch off ignition and remove ignition key!
â–² WARNING: Filter fuel (using filter funnel) when filling the tank. Use only
clean, non-translucent safety approved fuel containers.
â–² WARNING: Only handle fuel in well ventilated places. Never fill fuel in
enclosed spaces. Gasoline is highly inflammable and explosive.
Do not smoke, do not allow open flames or sparks in the vicinity.
Do not fill the tank to the brim, allow for expansion of the fuel.
Never refuel while engine is running.
For further information, see SI-912-016 and SI-914-019 “Operating fluids“,
latest issue.

Table of Contents

Other manuals for Rotax 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 Series and is the answer not in the manual?

Rotax 912 Series Specifications

General IconGeneral
Redline5800 rpm
TBO2000 hours
Displacement1211 cc
Bore79.5 mm
Stroke61 mm
Power Output80 hp (59.6 kW)
Compression Ratio9.0:1
Fuel TypeAvgas 100LL
Ignition SystemDual electronic ignition
Fuel SystemFuel Injected
Oil SystemDry sump
Engine Type4-cylinder, horizontally opposed, 4-stroke