74-00-00
page 16
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02624
BRP-Rotax
Maintenance Manual
3.7) Generator coils
See Fig. 74-12.
If the generator does not work, the reason may be a defective or damaged yellow
alternator cable or a defective winding on the 8 alternator coils (3). Disconnect
alternator cables (yellow) and check resistance values.
â—† NOTE: If the value measured corresponds with the values specified, the
cause may be a defective rectifier-regulator.
â–  CAUTION : When performing any of the work described here, ensure that
no foreign objects can enter the ignition unit.
Measure the resistance with a multimeter. See 74-00-00 sec. 3.12 and
74-00-00 sec. 5.

Table of Contents

Other manuals for Rotax 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 Series and is the answer not in the manual?

Rotax 912 Series Specifications

General IconGeneral
Redline5800 rpm
TBO2000 hours
Displacement1211 cc
Bore79.5 mm
Stroke61 mm
Power Output80 hp (59.6 kW)
Compression Ratio9.0:1
Fuel TypeAvgas 100LL
Ignition SystemDual electronic ignition
Fuel SystemFuel Injected
Oil SystemDry sump
Engine Type4-cylinder, horizontally opposed, 4-stroke