Effectivity 914 Series
Edition 1 / Rev. 0
76-00-00
page 21
May 01/2007
d02626
BRP-Rotax
Maintenance Manual
Legend to monitor display
(2) Rev counter display
(3) Throttle valve position
(4) Pressure difference between (8) and (9)
(5) LOG status ON/OFF
(6) Target pressure on basis of throttle valve position
(7) Target pressure on basis of pressure ratio between (9) and (10)
(8) effective target pressure input
(possibly reduced, e.g. by overspeeding, airbox temperature or too high pressure
ratio)
(9) Airbox pressure
(10) Ambient pressure
(11) Servo position
(12) not activated
(13) Target pressure reduction by exceeding of the max. airbox temperature
(14) Target pressure reduction by exceeding max. engine speed
(15) Airbox temperature
(16) Knocking signal (not activated)
(17) LOG actuation ON/OFF
(18) Software status
(19) Program identification
(20) Servo output %
(21) D factor
(22) I factor
(23) P factor

Table of Contents

Other manuals for Rotax 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 Series and is the answer not in the manual?

Rotax 912 Series Specifications

General IconGeneral
Redline5800 rpm
TBO2000 hours
Displacement1211 cc
Bore79.5 mm
Stroke61 mm
Power Output80 hp (59.6 kW)
Compression Ratio9.0:1
Fuel TypeAvgas 100LL
Ignition SystemDual electronic ignition
Fuel SystemFuel Injected
Oil SystemDry sump
Engine Type4-cylinder, horizontally opposed, 4-stroke

Related product manuals