Further shortcomings can only be detected in correlation with
the respective component of the turbo control unit.
CAUTION: The following checks are necessary if the TCU
is to be replaced.
- Inspection of the throttle valve position using the commu-
nication program. See 76-00-00 sec. 3.1.
CAUTION: If this aid is not at your disposal, a trial run of
the engine is required. Engine operation is
only allowed for transfer to the nearest
maintenance facility, where this check has
to be conducted afterwards.
- Test run engine. See the corresponding Maintenance
Manual (Line Maintenance) for the respective engine type,
912 Series or 914 Series.
- When switching on the TCU, observe self test of the servo
motor, see 76-00-00 sec. 3.1.2.7 and the caution lamps,
see 76-00-00 sec. 3.1.2.2.
WARNING: If an inspection reveals irregularities, then the
engine must not be taken in operation until the
cause is found and rectified.