EasyManuals Logo

Rotax 914 series Maintenance Manual

Rotax 914 series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #450 background imageLoading...
Page #450 background image
80-00-00
page 10
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02629
BRP-Rotax
Maintenance Manual
Bearings
Check bearing socket (13) and if necessary, replace the complete rotor bearing.
Carbon brushes
Carbon brushes (14) must move freely in their guides (15). Replace too short
brushes (min. length 8 mm = 0.32 "). Check spring pressure, replace hot-run
brush springs (16). Check connector sheaths (17) of the positive-pole carbon
brush (18), replace as required.
O-rings
Replace all O-rings (19) and oil seal (20) when repairing the electric starter.
Starter housing
Carry out visual inspection of the inner magnets (21) for cracks.
Studs
Carry out visual inspection of both studs (22) or allen screws (24).

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm