6.2) Temperature- and pressure observation
Engines of the 912 Series and 914 Series are equipped with two tempera-
ture control points on the cylinder heads for the coolant, one temperature
control point for the oil temperature and a pressure control point for the oil
pressure.
On engines of the 914 Series: The engine is also equipped with control
points for measurement of the airbox pressure, airbox temperature and the
ambient pressure.

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm