79-00-00
page 10
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02628
BRP-Rotax
Maintenance Manual
2.4) Magnetic plug
See the corresponding Maintenance Manual (Line Maintenance) for the respec-
tive engine type, 912 Series or 914 Series.
2.5) Drain plug
See the corresponding Maintenance Manual (Line Maintenance) for the respec-
tive engine type, 912 Series or 914 Series.
2.6) Connections for instrumentation
â–  CAUTION: Consult also the relevant section in the Installation Manual.
2.6.1) Oil pressure indication
Via an electric resistance pick-up attached on oil pump housing with
connection to indicating instrument.
2.6.2) Oil temperature indication
The sensor for the oil temperature is fitted in the oil pump housing. The
sensor is a thermo switch with changing internal resistance according
to oil temperature.

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm