76-00-00
page 30
May 01/2007
Effectivity 914 Series
Edition 1 / Rev. 0
d02626
BRP-Rotax
Maintenance Manual
- Check the display at max. continuous performance.
CAUTION: Throttle lever must be in positive stop position.
nominal: 100 % max. deviation +3%.
WARNING: This check of position is only meaningful and
permissible if idle- and full throttle-position are
within the permissible tolerances.
If the throttle position for idle and full throttle are not within the
permissible tolerances or if not proceeding linearly, then a new
calibration of the throttle position is absolutely necessary.
Recalibration to be carried out only by an authorized ROTAX-
Dealer or Service Center if the TCU is of part no. 966470 to
966473 .
If TCU part no. 966741 or higher is used, proceed with
calibration as described in the following section.