Effectivity 912/914 Series
Edition 1 / Rev. 0
74-00-00
page 55
May 01/2007
d02624
BRP-Rotax
Maintenance Manual
3.22) Rev counter and ignition trigger coils
See Figs. 74-36 and 74-37.
NOTE: All 5 trigger coils are of equal design. Therefore this checking
procedure is valid for the ignition trigger coils too.
The rev counter trigger coil (3) is fitted on the ignition housing.
- Inspect for physical damage.
- Inspect all connections
CAUTION: Any parts which have suffered physical damage or are not
functioning correctly must be replaced without delay. For mea-
surement values, see 74-00-00 sec. 3.12.
00094
3
Fig. 74-36