EasyManua.ls Logo

Ruide RCS - 3.5.1 OSET; 3.5.2 Enter the Horizontal Angle; 3.5.3 Face-1;Face 2 Measurement

Default Icon
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
1) All options in each item in measurement setting:
Target: Prism, sheet and non-prism.
PSM-C: Input prism constant directly (under prism mode). Scale: -999999mm
Mode: Single, 2 times, 3 times, 4 times, 5 times, Repeat, Tracking.
Record: Enter to record, Auto record, Only measure. This mode controls the mode operation of [MSR1]/MSR2]
in basic measurement function.
IfEnter to record is adopted, a screen ofRec Pt” is displayed to inform the user to check and confirm before
data is recorded.
“Auto record is a quick shooting and recording mode. The instrument automatically records the point using the
default PtID, and then returns to the basic measurement screen.
Only measure is the default measuring mode. After a measurement, the instrument stops in the BMS and
waits for you to press [REC/ENT] before recording the point.
2) The measurement mode setting of [MSR2] is the same as it. When pressing [MSR1] or [MSR2],
the system activates the corresponding measurement mode to measure.
3.3 HOT KEY
[HOT] Key includes the inputting function of target height, temperature & pressure, target selection and
note. It is available on any observation screen.
3.3.1 Set the Height of the Target
To change the height of the target (HT) or temperature, pressure, press [HOT].
Press [HOT] to display the [HOT] key menu.
Press [1] to enter into HT setting function.
Enter the height of the target manually.
Press [REC/ENT] to return to basic
measurement screen.
3.3.2 Set the Temperature & Pressure
Atmosphere Correction:
The speed of light in air is extremely fast. And it is not a constant, but changes with the temperature and
pressure of atmosphere. Once atmosphere correction is set, this instrument can implement atmosphere
correction automatically.
Hotkey
1.
R.HT
2.
T&P correction
3.
Target
4.
Comment
Back
R.HT 123
R.HT
1.500
m
Back
OK

Table of Contents

Related product manuals