14. ERROR CODE LIST
ERROR CODE
DESCRIPTION
SOLUTION
System Error 001
Error in opening the system parameter
file
Format. If format is invalidation, the
instrument should be sent for
repair.
System Error 002
Error in opening files
System Error 003
Error in initializing files
System Error 004
Error in writing files
System Error 005
Error in reading files
System Error 006
Error in deleting files
System Error 007
Error in hardware parameter
System Error 034
Upper vertical CCD error
1. Change a good angle board to
check whether it works.
2. If no, change this CCD.
System Error 035
Shorter horizontal CCD error
System Error 036
Longer horizontal CCD error
System Error 037
Lower vertical CCD error
ERROR36
Problem with internal light path signal
If the signal is 0, change the laser
emitter or fiber.
ERROR32
Problem with dimmer motor system
Change or reinstall the dimmer
motor