6.4 REFLINE STAKEOUT
This function allows you to stake out a point based on the relationship to a specified line.
In [SO] menu press [4] to enter to Ref.Line
stakeout function.
Enter the start point (P1) and the end point
(P2) of the line.
Enter offsets to the line. And press [Next]
F+B-:Distance from P1 along the line.
L-R+:Offset to baseline
(+): Right side of the P1-P2 line
(-): Left side of the P1-P2 line
U+D-: dVD to line
Start staking out. First Rotate the instrument
until the HAD displays as 0°00′00″.
Sight the target and press [MSR] to start
measuring.
The differences between the target position
and the stakeout point are displayed.
Move the prism forward or backward
according to the arrowhead until all the values turn
to be 0.
Press [ENT] to record the stakeout point.
Press [Change] to stake out another point.
6.5 GUIDE LIGHT
By emitting two visible beams of coherent light, one red and one yellow, enabling the rodman to locate the
correct line quickly and easily by finding the position where both light blink alternately.
Press numeric key [8] to enter to stake-out function. The screen will show “Open the guiding light?”. Press
[MSR1] to cancel or press [ANG] to activate the guide light function.